How do Maximo report record limits, the report queue and report scheduling work?

Report limits are set in Report Administration, on the report and on the security group, not in system properties.

Versions: On Maximo Application Suite 9.1 we confirmed, read-only, that the same settings, system properties, cron tasks and messages are present, with the same default values (17 November 2026). We first read them in our lab on Maximo 7.6.1.0 (3 November 2026). How the queue and scheduling behave is from IBM’s documentation; we have not run a scheduled report on either version.

IBM’s page: IBM’s current Maximo Manage documentation covers the Report Administration application; that page does not describe these limits.

Last checked: 17 November 2026

How it works

LimitWhere you set itMessage
Per-report record limit: Limit Records and Max Record LimitReport Administration, report’s Report tabBMXAA3512E “Result set exceeds maximum allowed count…”
Report Server Records LimitSelect Action > Set Security Group LimitsIBM’s 7.6 documentation: the run is cancelled on the report server when the whole report passes the limit.
Scheduled Reports LimitSame dialogBMXAA8037E
Ad Hoc Preview Records LimitSame dialogBMXAA8768E

When a user is in more than one group, the property mxe.report.MaxReportLimits decides: 1 (the default) uses the highest group limit.

The queue. Every run goes to the report queue. On each server, the queue manager starts at most mxe.report.birt.maxconcurrentrun reports at once (default 5) and checks the queue every mxe.report.birt.queueidletimeseconds seconds (60). The report’s Priority orders waiting jobs. View Report Processing shows running jobs, and an administrator can cancel one there (IBM; we did not cancel a job).

Scheduling. On the request page the user chooses At this Time or Recurring and the e-mail options. Maximo stores the schedule and creates an instance of the REPORTSCHEDULE cron task that runs as that user. Other report cron tasks: REPORTLOCKRELEASE (scheduled every minute as delivered), REPORTUSAGECLEANUP and REPORTOUTPUTCLEANUP.

What we read on both systems: the limits are fields on the report and on the security group, not system properties. The one property involved is mxe.report.MaxReportLimits. Maximo also has a separate message for a scheduled report that passes its limit when it runs (BMXAA8909E).

Steps

  1. Per-report limit: Report Administration > open the report > Report tab > Settings. Tick Limit Records and enter Max Record Limit (a whole number above 0). Save, then Generate Request Page.
  2. Group limits: Select Action > Set Security Group Limits. Select the group and enter the three limits. OK.
  3. Heavy reports at night only: Performance tab > Reserved Processing Time > New Row. With Schedule Only, users can only schedule the report.
  4. To see or delete schedules: Select Action > View Scheduled Reports.
  5. To watch or cancel running reports: Select Action > View Report Processing.

Where it breaks

How we checked it

On a Maximo 7.6.1.0 lab system we read the report settings, the group limit fields, the Set Security Group Limits dialog, the report properties and the report cron tasks with read-only queries. On Maximo Application Suite 9.1 we read the same items, also read-only, and compared them: the names, default values and message texts are the same.

Not tested: the limit message on screen, scheduling (it creates a cron task and sends e-mail), group limits on shared groups, cancelling a job.

This page is part of our Maximo knowledge pages: answers we have checked on a real Maximo system in our lab. For questions about your own Maximo data, see Interpretos for Maximo.